Application 1.25" BS zinc plated chain used in a water environment.
Failure mode Bushes fractured on assembly.
Diagnosis Customer supplied zinc plated bushes for assembly. When assembled the bushes broke into several fragments due to hydrogen embrittlement as they had not been de-embrittled after plating.
Solution Ensure correct de-embrittlement treatment is carried out immediately after plating.